Tuesday, November 18, 2014

GM engineers bullet-resistant CNG tank for bi-fuel Impala

Will we be seeing more CNG cars being that “clean natural gas” is so plentiful these days?
Is this car good reason to buy GM’s version over a do-it-yourself conversions?
This is of course more of that “all of the above” approach. Others might like to see the effort spent on electrification.

2015-Chevrolet-ImpalaBi-Fuel-001-medium
Chevrolet has gone to great lengths to ensure the safety of the Impala’s natural gas tank.
The company stated being able to take a bullet and withstand fires from multiple directions sets apart the compressed natural gas (CNG) tank in the 2015 Bi-fuel Chevrolet Impala from less-strenuous testing of other natural gas-powered vehicles.
2015_Chevrolet_Bi-Fuel_Impala_Crash-668
height=”409″ />Chevrolet explained a large piece of cast aluminum helps protect the tank valve and connection from certain side impacts while sheet metal plates on either side of the tank help protect it from loose objects in the trunk or rear seat.
“We designed this system for those ‘what if’ situations,” said Nichole Kraatz, Impala chief engineer. ”The customer shouldn’t even know it’s there. They shouldn’t even think about it. CNG should just be another fuel they use to power their vehicle.”
According to Chevrolet, durability and safety testing at the tank’s normal operating pressure of 3,600 PSI and higher subjected it to normal and extreme situations, exceeding federal requirements and CNG industry guidelines. The company gave these test protocols as examples of what the tank can withstand:
  • The industry-standard Bonfire Test confirms the CNG tank’s pressure relief valves are operational and help prevent the tank from rupturing in a fire. In addition to placing the tank about four inches above a steady 800-degree Fahrenheit fire, General Motors’ engineers added trunk, back seat and underbody fires to test the pressure relief valves’ ability to sense heat on all sides of the tank. And the tests were done at two different fuel levels.
  • In the Penetration Test, the tank is filled to its service pressure and is shot with a 7.62 mm armor piercing bullet. In order to pass the test, the bullet has to pass completely through one side of the tank without exiting out the other side. The goal is to have the tank maintain the bullet hole only as the weak structural point, without rupturing.
  • Front barrier, side impact and rear impact crash tests were conducted on the Bi-Fuel Impala. Some aftermarket CNG-conversion kit manufacturers conduct only a barrier test.
The tank also undergoes long-term structural integrity tests equivalent to 15,000 pressure cycles and hydrostatic bursting tests of up to 8,100 PSI, added Chevrolet.
The Bi-fuel Impala runs on both CNG and gasoline; it is available to order now through all Chevrolet dealerships in the US and Canada with delivery expected at the end of this year.
Chevrolet stated the all-steel trunk-mounted CNG tank holds approximately 7.8 gallons, sufficient for about 150 miles of driving after which the Impala seamlessly switches to gasoline power.
2015-Chevrolet-Bi-Fuel-Impala-Safety-Infographic

No comments: